The aim of this work was to develop and validate a dissolution test for Eperisone Hydrochloride in Tablets using spectrophotometric method. The dissolution established conditions were 0.1N HCL 900 mL for 2 hrs as dissolution medium, using a(USP-II) paddel apparatus at a rotating rate of 75 rpm. The drug release was evaluated by UV spectrophotometric method at 261 nm. The method was validated to meet requirements for a global regulatory filing. The validation included specificity, linearity, precision and accuracy.