The Indonesian government should seriously consider the use of renewable energy, given the natural potential that can still be utilized as an environmentally friendly power source. The utilization of renewable energy can be achieved by harnessing available natural resources. Pico hydro power plants (PLTPHs) can serve as an alternative electricity generator for use in Indonesia due to the existing natural potential. The output from this power plant can be utilized directly or stored in batteries. Directly measuring the generator’s performance on-site is deemed less effective. Therefore, a monitoring system is introduced as a solution to allow remote monitoring and display parameters such as voltage, current, frequency, and power of the generator online. This system is designed to display the micro hydro generator’s output parameter data on the Blynk application. The display on the Blynk application can be monitored via a connected mobile phone. Testing of the monitoring system was carried out by comparing two sets of measurements: one through the PZEM-004T sensor system and the other through a kWh meter (Kilowatt-hour meter). For the AC output from the battery with a 12-watt lamp load (tested 4 times), the reading error values obtained were a voltage reading error of 0.2%, a current reading error of 19.4%, a frequency reading error of 0.67%, and a power reading error of 18.2%.