Current Issue : January-March Volume : 2023 Issue Number : 1 Articles : 5 Articles
The carry look-ahead adder (CLA) is well known among the family of high-speed adders. However, a conventional CLA is not faster than other high-speed adders such as a conditional sum adder (CSA), a carry-select adder (CSLA), and the Kogge–Stone adder (KSA), which is the fastest parallel-prefix adder. Further, in terms of power-delay product (PDP) that characterizes the energy of digital circuits, the conventional CLA is not efficient compared to CSLA and KSA. In this context, this paper presents a high-speed and energy-efficient architecture for the CLA. Many adders ranging from ripple carry to parallel-prefix adders were implemented using a 32-28 nm CMOS standard digital cell library by considering a 32-bit addition. The adders were structurally described in Verilog and synthesized using Synopsys Design Compiler. From the results obtained, it is observed that the proposed CLA achieves a reduction in critical path delay by 55.3% and a reduction in PDP by 45% compared to the conventional CLA. Compared to the CSA, the proposed CLA achieves a reduction in critical path delay by 33.9%, a reduction in power by 26.1%, and a reduction in PDP by 51.1%. Compared to an optimized CSLA, the proposed CLA achieves a reduction in power by 35.4%, a reduction in area by 37.3%, and a reduction in PDP by 37.1% without sacrificing the speed. Although the KSA is faster, the proposed CLA achieves a reduction in power by 39.6%, a reduction in PDP by 6.5%, and a reduction in area by 55.6% in comparison....
The article is devoted to the study of steady-state conditions of a distribution network containing a thyristor voltage regulator. The thyristor voltage regulator (TVR) is a new controlled semiconductor device developed at Nizhny Novgorod State Technical University n.a. R.E. Alekseev (NNSTU). The TVR allows the optimization of the parameters of 6–20 kV distribution networks (currents and voltages) by voltage regulation. An analytical calculation of electromagnetic processes of a distribution network with the TVR has been carried out. The verification of the obtained results has been made using a computer simulation. The dependences of the current and power on additional voltage introduced by the TVR under different voltage regulation modes have been obtained. It has been shown that the use of the TVR enables optimal flow distribution to be ensured over the power transmission lines in proportion to their transfer capability when changing load power and its power factor....
This paper presents a tool that evaluates the applicability of a fault diagnostics technique (FDT) for Switch-Mode Non-Isolated DC-DC converters (SMNI DC-DC). The proposed tool simulates the operation of a Type II controller for a buck converter under different operating conditions and, simultaneously, implements the FDT. In this way, it is possible to evaluate the applicability of the FDT in real-time. The proposed tool is implemented in Python, and requires the partitioning of the code into different modules. The first module is responsible for modeling the different states of the converter. The second module contributes to the production of the PWM signal. The concepts of symmetry and asymmetry are implicit to the signal processing methods used in the design of the FDTs that compose the third module. Finally, all of the modules are properly included in the main function, which represents the fourth module. The validation of the proposed tool is carried out by comparing the results with the LTspice simulator and with an experimental prototype built for this purpose. Different operating conditions are considered. In addition to the proposed tool, an algorithm for the design of both the power section and the converter compensator is presented....
In order to keep the flux constant when the asynchronous motor is running under load, especially under light load, a Glowworm swarm optimization (GSO) algorithm is proposed to control the voltage frequency ratio of the cycloconverter. Based on the analysis of the two variable control theory of the voltage frequency ratio of the cycloconverter and the working principle of the cycloconverter, the self-control method of the voltage frequency ratio of the cycloconverter by adaptive fuzzy backstepping sliding mode is proposed. In the control process, GSO and BFA are integrated to optimize the control process of the controller, and an adaptive selection strategy is adopted to ensure the adaptive step size of the firefly and improve the accuracy of the GSO algorithm. The experimental results show that when the optimal voltage-frequency ratio is switched between the online continuous frequency control strategy and the frequency range is small enough, the motor speed is stable, the speed regulation process is stable, and the motor is always in the state of high force index. It shows that the control method has a fast convergence speed and a good control effect on the voltage frequency ratio of the ring converter of the experimental motor, and it can keep the flux constant under light load....
In this paper, static voltage stability assessments and their improvement using analytical and optimization techniques with different loading scenarios are described. In this study, the 400 kV, 230 kV, and 132 kV Ethiopian electric power networks are modeled using Power System Analysis Toolbox (PSAT), and the load flow analysis is carried out using MATLAB source code. Then, different voltage stability indices, such as the user-defined advanced voltage stability index (AVSI), modified voltage stability index (MVSI), and fast voltage stability index (FVSI), are used to identify the voltage unstable buses. Besides this, particle swarm optimization (PSO) is also used to find the optimal size and placement of the Static Synchronous Compensator (STATCOM) for the most severe buses identified by voltage stability indices. The result presents three special arguments: whether the most severe buses that are ranked at the top based on the voltage stability indices are optimal buses for compensation placement or not, the voltage stability improvement, and power loss reduction with the introduction of STATCOM. Accordingly, it is observed that the weakest bus that is identified through the stability indices may not be the optimal placement of the compensation device. It is also indicated that, with the introduction of STATCOM to the optimal selected bus, the network power loss is reduced from 46.65MW to 33.32MW and its voltage magnitude in all buses is also improved. All bus voltages are within the IEEE standard acceptable limit....